Pullman Power

 

Installation of liner support system

 

Gibson Station FGD Retrofit
Gibson County, Indiana

Constantly striving to provide the optimal pollution control, this Midwestern Utility opted to retrofit a new flue gas desulphurization system with a new chimney. Design work for the project began in December 2003 and crews entered the field in August 2004. Pullman Power was awarded the project to provide the chimney design and construction of the environmentally-friendly solution.

Several design solutions were evaluated for the project. The first strategy specified a top-hung liner support system that would have added a level of support and an expansion joint to the structure. Instead of this approach, the owner selected a solution that provided support right above the breeching that eliminated the expansion joint and minimized the stresses in the breeching area. This approach was selected because it was the most cost-effective solution for meeting the owner's goals.

The project involved the installation of a C-276 high nickel alloy clad (roll bonded) liner. The liner was erected by bringing the prerolled plate rings into the chimney at the base in sections. Approximately 10-foot tall liner sections (cans) were welded together at the base. Carbon steel stiffeners were welded to the completed cans and 2 inches of insulation was installed on the exterior prior to adjoining the sections and lifting with the use of hydraulic jacks. The rainhood was constructed using solid C-276 plate.

One of the challenges of this project was that this work had to be conducted within the confines of the existing plant while the plant was in operation. The project utilized 230 tons of reinforcing steel and 2,700 cubic yards of concrete. The chimney is nominally 620 feet tall with a 25-foot interior diameter alloy steel liner.

Chimney Data:

Bottom Outside Diameter

44 feet

Top Outside Diameter

33 feet, 6 inches

Method of Construction

Jumpform

Design Code

"Standard Practice for the Design and Construction of Cast-In-Place Reinforced Concrete Chimneys (ACI 307-88)"

 

 

Liner Data:

Number of Liners

One

Inside Diameter

25 feet

Material

C-276 high nickel alloy roll bonded clad plate

Support Conditions

Supported above the breeching by structural steel grillage

Breeching Entry

Single rectangular / tapered

Gas Temperature

135° F

Liner Pressure

± 4" w.g.

Gas Flow

2,130,000 lb/hr


Copyright 2010 Pullman Power, LLC - A Structural Group Company